Pilot600 / 600R Chromatography systems

Pilot600 / 600R Chromatography systems

简介:

  • Flow range:0~1200mL/min option
  • Pressure:up to 2.0MPa(20bar / 280psi)
  • Wavelength range:(190-500)three wavelengths /(195-850nm)four wavelengths
  • Wavelength:three wavelengths / four wavelengths simultaneously
  • Absorance: ±6AU
  • Communication:TCP/IP

Scope of application

Universal pilot-grade protein purification system with modules that can be added or removed. Applications from laboratory to industrial grade R&D and production of biological proteins, antibodies, vaccines, etc. It mainly serves major biological companies, CROs, and CDMO companies, providing them with complete solutions for R&D and production.

 

Inquiry Online Service

Item Parameter Memos
Interface Hy-Hass系列模块化蛋白纯化系统 ( L x H x D) –[mm]: 520 x 750 x 440
Pump Flow range: 0~1200mL/min
Pressure: 2MPa(20bar / 280psi )
Accuracy:±2%,0.7 - 5cP
Gradient accuracy:±2%
Communication:TCP/IP
Pressure sensor: (0~10MPa) Precision:±0.025MPa
Cleaning: Automatic cleaning
Twin Pump Gradient - (600mL/mL per pump)
constant pressure mode, pressure control mode
Mixer Dynamic mixer: 5mL, Option(10 mL、15mL) Default 5mL
UV detector Abs:±6AU
Option:190-500nm three wavelength Simultaneously
Option:190-850nm four wavelength Simultaneously
Option:190-500nm three wavelength Simultaneously 
Cond/Temperature Conductivity 0-999 mS/cm, graduation 0.001, error ± 1.0% (0-300ms/cm) Automatic temperature compensation
Optional: Selective pre-column conductance
default:Post-column conductance
pH pH 0-14,Graduation:0.01, Precision:  ± 0.15 pH flow cell + electrode
Communication TCP/IP(100M) Default
Fittings Pipe fittings and other accessories Default
Work station Chinese and English interface, including instrument control, method preparation, data processing and printing report functions, user and experimental results database, encrypted database management users and experimental results, support peak integration, quantitative calculation, audit trail, scouting, channel scouting, method programming function and multi channels joint work Default
Inlet A Inlets (option: 3, 6, 9 Channels) 3 channels:3 inPort + 1 outPort
Inlet B Inlets (option: 3, 6, 9 Channels) 3 channels:3 inPort + 1 outPort
Air sensor A option(ultrasonic Hold Up Volume: 30uL-1mL) default:none
Air sensor B option (ultrasonic Hold Up Volume: 30uL-1mL) default:none
Air sensor post column option (ultrasonic Hold Up Volume: 30uL-1mL) default:none
Online filters option default:none
Column 1 position, 1 column flow path, 1 channel by pass, forward and reverse
option: 2 positions, 1 column flow path, 1 channel by pass, forward and reverse
Default: 1 post valve, forward and reverse flush, 1 way by pass
Column press Pre-column pressure, post-column pressure, Delta pressure default
outlet outlets (Option: 3, 6, 9, 12, 15 Channels) 3 Channels:3 outPort + 1 inPort
AB pump restrictor HY-RT600,0.2MPa background pressure default
Communication instruction Customize the optimized instruction design, and provide the .net format and C/C++DLL format through the test development library, and provide the sample source code It can be used for secondary development.
Computer win7/win10/win11 Intel i3 and Above, Memory ≥8GB, Disk ≥256GB Display:1920x1080
Power 110v~220V(AC),±5%  
Temperature -10~40℃,No condensation  
Items Parameter Memo
Interface Hy-Hass系列模块化蛋白纯化系统 ( L x H x D) –[mm]: 520 x 750 x 440
Pump Flow range: 0~1200mL/min
Pressure: 2MPa(20bar / 280psi )
Accuracy:±2%,0.7 - 5cP
Gradient accuracy:±2%
Communication:TCP/IP
Pressre sensor: (0~10MPa) Precision:±0.025MPa
Cleaning: Automatic cleaning
Twin Pump Gradient - (600mL/mL per pump)
constant pressure mode, pressure control mode
Mixer Dynamic mixer: 5mL, Option(10 mL、15mL) Default 5mL
UV detector Abs:±6AU
Option:190-500nm three wavelength Simultaneously
Option:190-850nm four wavelength Simultaneously
Option:190-500nm three wavelength Simultaneously
Cond/Temperature Conductivity 0-999 mS/cm, graduation 0.001, error ± 1.0% (0-300ms/cm) Automatic temperature compensation
Optional: Selective pre-column conductance
default:Post-column conductance
pH pH 0-14,Graduation:0.01, Precision:  ± 0.15 pH flow cell + electrod
Communication TCP/IP(100M) Default
Fittings Pipe fittings and other accessories Default
Work station Chinese and English interface, including instrument control, method preparation, data processing and printing report functions, user and experimental results database, encrypted database management users and experimental results, support peak integration, quantitative calculation, audit trail, scouting, channel scouting, method programming function and multi channels joint work Default
Inlet A Inlets (option: 3, 6, 9 Channels) 3 channels:3 inPort + 1 outPort
Inlet B Inlets (option: 3, 6, 9 Channels) 3 channels:3 inPort + 1 outPort
Air sensor A option(ultrasonic Hold Up Volume: 30uL-1mL) default:none
Air sensor B option (ultrasonic Hold Up Volume: 30uL-1mL) default:none
Air sensor post column option (ultrasonic Hold Up Volume: 30uL-1mL) default:none
Online filters option default:none
Column 1 position, 1 column flow path, 1 channel by pass, forward and reverse
option: 2 positions, 1 column flow path, 1 channel by pass, forward and reverse
Default: 1 post valve, forward and reverse flush, 1 way by pass
Column press Pre-column pressure, post-column pressure, Delta pressure default
outlet outlets (Option: 3, 6, 9, 12, 15 Channels) 3 Channels:3 outPort + 1 inPort
AB pump restrictor HY-RT600,0.2MPa background pressure default
Communication Instructions Customize the optimized instruction design, and provide the .net format and C/C++DLL format through the test development library, and provide the sample source code It can be used for secondary development.
Computer win7/win10/win11 Intel i3 and Above, Memory≥8GB, Disk ≥256GB Display:1920x1080
Power 110v~220V(AC),±5%  
Temperature -10~40℃,No condensation  
  • Protein purification
    Vaccine purification
    Antibody purification
    New drug research and development
    Laboratory research